Summary for Test 2021-08-25-35-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
| Award Date | 11/06/2018 |
| Closeout Date | 08/16/2023 |
| Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
| Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
| Sample Taken Date | 08/25/2021 | Sample Unique Key | 35 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/25/2021 | Sample type | Department Acceptance |
| A brief description of the sample | 3/8 Inch HMA-A 23.6 RAP PG58-22 Valero | The quantity of what the sample constitutes | PSE 8 Boxes, 100k Ton Milestone |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | J.D. |
| Last name of sampler or witnessed by | Atkinson | Title of sampler | Material Tester |
| Telephone number of sampler | Laboratory sample identification | D78928 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | J F Shea Construction Inc - Fawndale Rock and Asphalt - Redding CA | |
| Transportation Laboratory (TL) Number | 858988 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2021-08-25-35
DIME Test ID: 2021-08-25-35-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-09-09
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 08/26/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 2543.6 grams
Mass of container filled with the sample and water for Sample 1: 8905.6 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.61
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/9/2021 ✔