Summary for Test 2021-07-15-32-2

Test performed: AASHTO T59-16

Project Information

Project IdentifiersProject ID: 55555
DEA: AMRL
EFIS: AMRL
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL).
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/15/2021 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing07/23/2021 Sample typeProficiency
A brief description of the sampleEmulsion Proficiency Samples The quantity of what the sample constitutes2 emulsion, 75(A) 76(B) CSS-1H
From where was the sample collectedDistributor First name of sampler or witnessed byAASHTO resource
Last name of sampler or witnessed byAASHTO resource Title of sampler
Telephone number of sampler Laboratory sample identification75 76
Linked DIME Sample ID The fabricator/manufacturer/facility nameAASHTO resource
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2021-07-15-32
DIME Test ID: 2021-07-15-32-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2021-09-07

Test Results


Is Correction factor required?: No
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 09/07/2021
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Efflux time (ET) for test sample: 18.3 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 18 sec
Test efflux temperature: 25 F
General comments (publicly viewable) (Max 1000 characters): 76(B)

Test was verified on 9/7/2021 ✔