Summary for Test 2021-07-15-32-2
Test performed: AASHTO T59-16Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/15/2021 | Sample Unique Key | 32 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/23/2021 | Sample type | Proficiency |
| A brief description of the sample | Emulsion Proficiency Samples | The quantity of what the sample constitutes | 2 emulsion, 75(A) 76(B) CSS-1H |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | AASHTO resource |
| Last name of sampler or witnessed by | AASHTO resource | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 75 76 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AASHTO resource | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | CSS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2021-07-15-32
DIME Test ID: 2021-07-15-32-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2021-09-07
Test Results
Is Correction factor required?: No
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 09/07/2021
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Efflux time (ET) for test sample: 18.3 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 18 sec
Test efflux temperature: 25 F
General comments (publicly viewable) (Max 1000 characters): 76(B)
Test was verified on 9/7/2021 ✔