Summary for Test 2021-08-27-3-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214995
DEA: 040J5304
EFIS: 0414000010
DIST-CO-RTE-PM04-ALA-880-11.4/12.2
Award Date01/04/2021
Closeout Date04/26/2023
Work DescriptionPATTERSON SLOUGH BRIDGE DECK REHAB
Location DescriptionALAMEDA COUNTY IN FREMONT FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF PATTERSON SLOUGH BRIDGE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date08/27/2021 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing09/01/2021 Sample typeQuality Assurance
A brief description of the sampleLennton A2 The quantity of what the sample constitutesx
From where was the sample collectedFabricator First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerQA Inspector
Telephone number of sampler916-826-6371 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameC and N Reinforcing
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB22-074-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerLenton Intermediate Assembler or FabricatorC and N Reinforcing
Rebar Size#11 Coupler ModelA2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A180950 Rebar Heat Number(s)149821
Rebar Size 2 11 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-08-27-3
DIME Test ID: 2021-08-27-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-07

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/03/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 11/36mm101.5614304991698Service Splicebewing

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/7/2021 ✔