Summary for Test 2021-08-19-50-7
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/19/2021 | Sample Unique Key | 50 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2021 |
Sample type | Quality Control | A brief description of the sample | PG70-10 Asphalt Binder |
The quantity of what the sample constitutes | 1 of 2 cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Partenan |
Title of sampler | Sr Asphalt Technician | Telephone number of sampler | 6614327352 |
Laboratory sample identification | 7010210819 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | San Joaquin Refinery, Bakersfield, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | 7010210819 |
Sublot number | Tank number | 9001 | |
Time of sample | 10:25 am | HMA Supplier | |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-19-50
DIME Test ID: 2021-08-19-50-7
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-02
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: Sandra Ponce
Date of test: 08/20/2021
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 61.0 degree
(G*) x sin(δ)=: 3978 kPa
General comments (publicly viewable) (Max 1000 characters): Test @ 37C
Test was verified on 9/2/2021 ✔