Summary for Test 2021-08-19-46-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/19/2021 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2021
Sample typeQuality Control A brief description of the samplePG58-16 Asphalt binder
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byJohn Last name of sampler or witnessed byPartenan
Title of sampler Sr Asphalt Technician Telephone number of sampler6614327352
Laboratory sample identification5816210819 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
ModifiedNo Lot number5816210819
Sublot number Tank number2002
Time of sample10:45 am HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-19-46
DIME Test ID: 2021-08-19-46-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-09-01

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 08/19/2021
Observed Flash Point: 309 C
Ambient Barometric Pressure: 756 mmHg
Cleveland Open-Cup Flash Point in Celsius: 309 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/1/2021