Summary for Test 2021-08-26-22-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 214919 DEA: 060U4504 EFIS: 0615000298 |
---|---|
DIST-CO-RTE-PM | 06-FRE-168-18.6/T25.5 |
Award Date | 06/16/2020 |
Closeout Date | 07/29/2022 |
Work Description | COLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING. |
Location Description | FRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD |
QA Service Level | 1 (Verified on 04/21/2020) |
Sample Information
Sample Taken Date | 08/26/2021 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/27/2021 |
Sample type | Department Acceptance | A brief description of the sample | JMF |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Lopez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero Pittsburg | Transportation Laboratory (TL) Number | 039820 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-26-22
DIME Test ID: 2021-08-26-22-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-09-02
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 08/31/2021
Temperature: 25 C
Final Dial reading (F1): 76 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 76 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 74 mm
Ball Penetration (P3): 0 mm
Resilience 1: 24 %
Resilience 2: 24 %
Resilience 3: 26 %
Average Resilience: 25 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 9/2/2021 ✔