Summary for Test 2021-08-04-35-2
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/04/2021 | Sample Unique Key | 35 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2021 |
| Sample type | Informational | A brief description of the sample | RHMA |
| The quantity of what the sample constitutes | 12 Boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | AAA Tech | Last name of sampler or witnessed by | AAA Tech |
| Title of sampler | AAA Tech | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | AAA Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2021-08-04-35
DIME Test ID: 2021-08-04-35-2
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-09-01
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Marta Landaverde
Date of test: 08/04/2021
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Treated | ||||||
98 psi | 154 psi | |||||
64 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/1/2021 ✔