Summary for Test 2021-08-17-6-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 215296 DEA: 031F1504 EFIS: 0300001101 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-50-R7.7/R9.5 |
| Award Date | 02/05/2021 |
| Closeout Date | 10/04/2022 |
| Work Description | PLACE HMA, RHMA, AGGREGATE BASE AND FIBER OPTIC SYSTEM. |
| Location Description | SACRAMENTO COUNTY IN AND NEAR RANCHO CORDOVA FROM BRADSHAW ROAD OVERCROSSING TO MATHER FIELD OVERCROSSING |
| QA Service Level | 1 (Verified on 11/30/2020) |
Sample Information
| Sample Taken Date | 08/17/2021 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/18/2021 | Sample type | Department Acceptance |
| A brief description of the sample | Rubber | The quantity of what the sample constitutes | 1 CAN |
| From where was the sample collected | Source | First name of sampler or witnessed by | Jeff |
| Last name of sampler or witnessed by | Clason | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Perkins Batch Plant | |
| Transportation Laboratory (TL) Number | 850277 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | marathon |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-17-6
DIME Test ID: 2021-08-17-6-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-08-23
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 08/22/2021
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 72 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 70 mm
Ball Penetration (P3): 1 mm
Final Dial reading (F3): 73 mm
Resilience 1: 28 %
Resilience 2: 30 %
Resilience 3: 28 %
Average Resilience: 29 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 8/23/2021 ✔