Summary for Test 2021-07-27-31-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 215126
DEA: 010G33U4
EFIS: 0120000002
DIST-CO-RTE-PM01-LAK-20-5.1/6.3
Award Date11/19/2020
Closeout Date10/07/2022
Work DescriptionWiden shoulders and replace bridge with box culvert.
Location DescriptionLAKE COUNTY NEAR UPPER LAKE FROM 0.4 MILE WEST OF WITTER SPRINGS ROAD TO 0.4 MILE EAST OF BACHELOR CREEK BRIDGE
QA Service Level1 (Verified on 08/26/2020)

Sample Information

Sample Taken Date07/27/2021 Sample Unique Key31
Date that the sample was received by the laboratory/organization performing the testing07/27/2021 Sample typeQuality Control
A brief description of the sampleconc. cylinder The quantity of what the sample constitutes2
From where was the sample collectedFabricator First name of sampler or witnessed byDan
Last name of sampler or witnessed byWeippert Title of samplerQC Manager
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUniversal Precast Concrete
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberPC65A0E2
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected000814
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-07-27-31
DIME Test ID: 2021-07-27-31-1
Testing Lab: Precast Unlimited Inc.
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-08-19

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Mike Boak
Date of test: 08/03/2021
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 29 lb
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 103540 lb
Maximum load on cylinder 2: 103400 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 3660 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2021 ✔