Summary for Test 2021-07-26-37-3
Test performed: AASHTO T315-20Project Information
| Project Identifiers | Project ID: 215536 DEA: 09383504 EFIS: 0920000044 |
|---|---|
| DIST-CO-RTE-PM | 09-MNO-395-R40.1/R44.8 |
| Award Date | 05/13/2021 |
| Closeout Date | 11/30/2021 |
| Work Description | PLACE HMA OVER EXISTING PAVEMENT. |
| Location Description | MONO COUNTY ABOUT 7 MILES SOUTH OF LEE VINING FROM 0.2 MILE SOUTH OF ROUTE 158 TO 0.6 MILE NORTH OF LA AQUEDUCT BRIDGE |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 07/26/2021 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 | Sample type | Department Acceptance |
| A brief description of the sample | PG58-34M | The quantity of what the sample constitutes | 1 can |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | _ |
| Last name of sampler or witnessed by | _ | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | c661389 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | PNAC LLC - Fernley NV | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | Not set | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2021-07-26-37
DIME Test ID: 2021-07-26-37-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-26
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 08/16/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.181 kPa
Phase Angle (δ) (for the 10 cycles): 64.9 degree
Complex Modulus (G*) (for the 10 measurements): 1.506 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.66 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORG
Test was verified on 8/26/2021 ✔