Summary for Test 2015-09-11-1-2

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 5266
DEA: 08448404
EFIS: 0800000712
COOP: 081488A1
DIST-CO-RTE-PM08-RIV-91-15.6/21.6
Award Date02/10/2012
Closeout Date07/27/2023
Work DescriptionCONSTRUCT HOV LANES AND WIDEN BRIDGES.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM ADAMS STREET TO THE ROUTE 60/215 SEPARATION
QA Service Level1 (Verified on 04/27/2012)

Sample Information

Sample Taken Date09/11/2015 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/15/2015 Sample typeQuality Control
A brief description of the sample6X121 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byJOE AND AL
Last name of sampler or witnessed bySIEMERS AND ALINA Title of samplerASR AND SR
Telephone number of samplerUnknown Laboratory sample identification825-30
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameROBERTSONS
Transportation Laboratory (TL) Number91130 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierPM 5 6 21 6 Structure nameIVY ST OH BR 56C 0562 DECK
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collected1844 The batch plant ticket number from where the sample was collected1248437
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedNP Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-09-11-1
DIME Test ID: 2015-09-11-1-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-09-25

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 09/25/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 100000 lb
Maximum load on cylinder 2: 96520 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3524.9 psi
Compressive strength of cylinder 2: 3402.2 psi
Compressive strength (to nearest 10 psi): 3460 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/25/2015 ✔