Summary for Test 2021-07-07-36-6

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215534
DEA: 081K8404
DIST-CO-RTE-PM08-SBD-247-39.0/42.0&46.0/70.0
Award Date04/14/2021
Closeout Date03/08/2022
Work DescriptionRUBBERIZED HMA AND HIGH DENSITY POLYURETHANE MATERIAL INJECTION.
Location DescriptionSAN BERNARDINO COUNTY AT LUCERNE VALLEY FROM 0.5 MILE SOUTH OF CAMP ROCK ROAD TO 0.1 MILE SOUTH OF MIDWAY AVENUE AND FROM 1.1 MILES SOUTH OF HOLMES ROAD TO 1.2 MILES NORTH OF STODDARD VALLEY ROAD
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date07/07/2021 Sample Unique Key36
Date that the sample was received by the laboratory/organization performing the testing07/20/2021 Sample typeVerification
A brief description of the samplePG Asphalt Binder The quantity of what the sample constitutes1 Quart Can
From where was the sample collectedSupplier First name of sampler or witnessed byAlex Blue Diamond Materials
Last name of sampler or witnessed byAlex Title of sampler
Telephone number of sampler Laboratory sample identification0414-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Mojave CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-07-07-36
DIME Test ID: 2021-07-07-36-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-15

Test Results


Phase: RTFO residue
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 07/21/2021
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 86.1 degree
Dynamic Shear, G*/sin(δ): 3.03 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/15/2021 ✔