Summary for Test 2021-08-06-12-4
Test performed: AASHTO T315-16Project Information
| Project Identifiers | Project ID: 215609 DEA: 074W9404 EFIS: 0720000196 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-101-0.0/1.0 |
| Award Date | 05/06/2021 |
| Closeout Date | 07/14/2022 |
| Work Description | COLD PLANE AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT, SLURRY SEAL. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM ROUTE 10/101 SEPARATION TO SPRING STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
| Sample Taken Date | 08/06/2021 | Sample Unique Key | 12 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/09/2021 | Sample type | Verification |
| A brief description of the sample | PG Asphalt Binder | The quantity of what the sample constitutes | 1 Quart Can |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | QC |
| Last name of sampler or witnessed by | QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0452-21 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Blue Diamond-Victorville | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | Not set | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2021-08-06-12
DIME Test ID: 2021-08-06-12-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-12
Test Results
Phase: Original binder
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 08/11/2021
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 85.2 degree
Dynamic Shear, G*/sin(δ): 1.29 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2021 ✔
