Summary for Test 2021-08-10-2-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213099 DEA: 041A6614 EFIS: 0415000291 COOP: 042683A1 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-8.4 |
| Award Date | 11/30/2020 |
| Closeout Date | 12/12/2023 |
| Work Description | CONSTRUCTION ON STATE HIGHWAY IN MARIN COUNTY IN LARKSPUR |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/06/2020) |
Sample Information
| Sample Taken Date | 08/10/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/11/2021 |
| Sample type | Quality Assurance | A brief description of the sample | anchor bolt assemblies |
| The quantity of what the sample constitutes | 170 assemblies | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Pacific Bolt | Transportation Laboratory (TL) Number | c835675 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-031-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1201015428 | Nut Mfg. Lot Number(s) | 444961A |
| Washer Mfg. Lot Number(s) | none | Bolt Specification | A1554 gr 36 |
| Bolt Length(s) | 10" | Nut Specification | A563 |
| Washer Specification | none | Finish | Hot Dip Galv. |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 410101542840 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | yest green lube on nuts | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-08-10-2
DIME Test ID: 2021-08-10-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-08-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/11/2021
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1 | 444961A | 22795 | A563 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/11/2021 ✔