Summary for Test 2021-07-12-45-2

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 215182
DEA: 08476424
EFIS: 0816000186
DIST-CO-RTE-PM08-SBD-215,259-4.0/17.8,0.0/1.5
Award DateNot set
Closeout Date01/23/2023
Work DescriptionINSTALL FIBER OPTIC CABLE SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR SAN BERNARDINO ON ROUTE 215 FROM ROUTE 215/10 SEPARATION TO ROUTE 215/15 SEPARATION AND ON ROUTE 259 FROM ROUTE 259/215 SEPARATION TO ROUTE 259/210 SEPARATION
QA Service Level1 (Verified on 01/20/2021)

Sample Information

Sample Taken Date07/12/2021 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing08/02/2021 Sample typeQuality Assurance
A brief description of the sampleconcrete cylinders The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byDiyar
Last name of sampler or witnessed bySaadi Title of samplerASR
Telephone number of sampler Laboratory sample identification1033-712
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1439 The batch plant ticket number from where the sample was collected6137225
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSB RT 215 Post Mile 12.8 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-07-12-45
DIME Test ID: 2021-07-12-45-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-08-09

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bahman Baghai
Date of test: 08/09/2021
Average diameter of cylinder 1: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 120368 lb
Type of fracture pattern of cylinder 1: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Compressive strength of cylinder (to nearest 10 psi): 4260 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/9/2021 ✔