Summary for Test 2021-06-17-49-4
Test performed: CTM 204-June 2010Project Information
Project Identifiers | Project ID: 215627 DEA: 032G2004 EFIS: 0321000024 |
---|---|
DIST-CO-RTE-PM | 03-YOL-128-0.0/9.8 |
Award Date | 05/11/2021 |
Closeout Date | 01/20/2022 |
Work Description | PLACE RHMA AND REPLACE ASPHALT CONCRETE. |
Location Description | YOLO COUNTY IN AND NEAR WINTERS FROM PUTAH CREEK BRIDGE TO ROUTE 128/505 SEPARATION |
QA Service Level | 1 (Verified on 03/29/2021) |
Sample Information
Sample Taken Date | 06/17/2021 | Sample Unique Key | 49 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2021 |
Sample type | Verification | A brief description of the sample | 3/4" untreated Virgin Aggregate |
The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Sam | Last name of sampler or witnessed by | Mosallem |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Woodland Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-57-0006 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hot Bins | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-17-49
DIME Test ID: 2021-06-17-49-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2021-08-09
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 07/21/2021
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): 0
General comments (publicly viewable) (Max 1000 characters): JMF 21-031.
Test was verified on 8/9/2021 ✔