Summary for Test 2021-05-24-57-7
Test performed: AASHTO T324-14Project Information
| Project Identifiers | Project ID: 215424 DEA: 024G4404 EFIS: 0214000013 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-3-38.0/38.6 |
| Award Date | 04/05/2021 |
| Closeout Date | 08/14/2023 |
| Work Description | BRIDGE REPLACEMENT |
| Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD |
| QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
| Sample Taken Date | 05/24/2021 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2021 |
| Sample type | Verification | A brief description of the sample | Treated 3/4-inch Type A HMA (eq. PG 64-16) with 24.0 RAP and virgin PG 58-22 from Valero - Benicia |
| The quantity of what the sample constitutes | Verification of JMF 21-04-S01 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Devin | Last name of sampler or witnessed by | Owens |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D78806 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis - Nortstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 897296 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2021-05-24-57
DIME Test ID: 2021-05-24-57-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-08-06
Test Results
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 05/26/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: no data
Type and Amount of Anti-Stripping Additive: 1.0% Lime
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 2 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2 mm
Stripping Inflection Point (Wheel A): >25000
Stripping Inflection Point (Wheel B): >25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 25000
Impression at specified number of passes average: 2 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/6/2021 ✔