Summary for Test 2021-07-27-23-4

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 214190
DEA: 024G41U4
EFIS: 0218000047
DIST-CO-RTE-PM02-SIS,SIS-5-Var
Award Date08/26/2019
Closeout Date11/24/2021
Work DescriptionREPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location DescriptionSHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
QA Service Level1 (Verified on 07/09/2019)

Sample Information

Sample Taken Date07/27/2021 Sample Unique Key23
Date that the sample was received by the laboratory/organization performing the testing07/27/2021 Sample typeDepartment Acceptance
A brief description of the sample3/4 HMA-A 23.6 RAP PG58-34m Valero Benicia The quantity of what the sample constitutesPSE 16 Boxes at 118 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byRandy
Last name of sampler or witnessed byBibbins Title of samplerCGI
Telephone number of sampler Laboratory sample identificationD78911
Linked DIME Sample ID The fabricator/manufacturer/facility nameJ F Shea Construction Inc - Fawndale Rock and Asphalt - Redding CA
Transportation Laboratory (TL) Number990948 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-07-27-23
DIME Test ID: 2021-07-27-23-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-08-09

Test Results


Unit system used?: SI Units
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 08/02/2021
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Treated
150.0 mm150.0 mm150.0 mm150.0 mm150.0 mm150.0 mm
94.7 mm94.8 mm94.6 mm94.9 mm94.8 mm94.7 mm
3855.9 g3857.6 g3857.6 g3855.7 g3854.8 g3855.3 g
2268.6 g2274.8 g2276.3 g2271.5 g2270.3 g2275.7 g
3883.5 g3885.3 g3881.5 g3891.3 g3884.3 g3885.8 g
2.573 2.573 2.573 2.573 2.573 2.573
3945.9 g3940.6 g3940.5 g
94.9 mm94.9 mm94.9 mm
220 mmHg134 mmHg118 mmHg
21 inHg23 inHg24 inHg
5 minutes5 minutes5 minutes

1614.9 cm^3

1610.5 cm^3

1605.2 cm^3

1619.8 cm^3

1614.0 cm^3

1610.1 cm^3

2.388

2.395

2.403

2.380

2.388

2.394

7.2 %

6.9 %

6.6 %

7.5 %

7.2 %

7.0 %

116.3 cm^3

111.1 cm^3

105.9 cm^3

121.5 cm^3

116.2 cm^3

112.7 cm^3

3937.3 g

3935.4 g

3931.7 g

3948.9 g

3946.5 g

3942.3 g

1618.6 cm^3

1609.7 cm^3

1607.3 cm^3

90.0 cm^3

83.0 cm^3

82.9 cm^3

77 %

75 %

78 %

24665 N

22512 N

21142 N

23758 N

25404 N

25760 N

0

0

0

0

0

0

17

17

16

24

31

15

0

0

0

0

0

0

1103 kPa

1007 kPa

946 kPa

1063 kPa

1137 kPa

1154 kPa

148 psi

162 psi

0.91
General comments (publicly viewable) (Max 1000 characters): Data missing for Wet #3 thickness after conditioning so assumed 94.9

Test was verified on 8/9/2021 ✔