Summary for Test 2021-07-27-2-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 213099 DEA: 041A6614 EFIS: 0415000291 COOP: 042683A1 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-8.4 |
| Award Date | 11/30/2020 |
| Closeout Date | 12/12/2023 |
| Work Description | CONSTRUCTION ON STATE HIGHWAY IN MARIN COUNTY IN LARKSPUR |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/06/2020) |
Sample Information
| Sample Taken Date | 07/27/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/02/2021 |
| Sample type | Quality Assurance | A brief description of the sample | Wire Rod |
| The quantity of what the sample constitutes | 170 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 4156081742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-055-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1201015428 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Grade 36 | |
| Bolt Length(s) | 10" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | HDG |
| Diameter/Size | .50" | Bolt Mfg. Lot Number | 410101542840 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-07-27-2
DIME Test ID: 2021-07-27-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-08-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/04/2021
UTM: 400kip
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | UNC 1/2 | 0.1419 | 10463 | 46 | 73709 | 64935 | 9214 | F1554 Anchor Rod Axial PULL |
General comments (publicly viewable) (Max 1000 characters): F1554 Anchor Rod Axial PULL
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/4/2021 ✔