Summary for Test 2021-05-24-56-2
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 215424 DEA: 024G4404 EFIS: 0214000013 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-3-38.0/38.6 |
| Award Date | 04/05/2021 |
| Closeout Date | 08/14/2023 |
| Work Description | BRIDGE REPLACEMENT |
| Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD |
| QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
| Sample Taken Date | 05/24/2021 | Sample Unique Key | 56 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2021 |
| Sample type | Verification | A brief description of the sample | 1/2-inch RAP (Combined) |
| The quantity of what the sample constitutes | Verification of JMF 21-04-S01 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Devin | Last name of sampler or witnessed by | Owens |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D78807B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis - Nortstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 897294 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | 1/2-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-05-24-56
DIME Test ID: 2021-05-24-56-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2021-08-12
Test Results
Does this test use 1/4 sieve?: Yes
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 05/27/2021
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1591.6 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 69.0 grams | 95.7 % | |||||
| 232.5 grams | 85.4 % | |||||
| 473.6 grams | 70.2 % | |||||
| 603.1 grams | 62.1 % | |||||
| 887.5 grams | 44.2 % | |||||
| 1083.8 grams | 31.9 % | |||||
| 1221.0 grams | 23.3 % | |||||
| 1336.0 grams | 16.1 % | |||||
| 1408.8 grams | 11.5 % | |||||
| 1453.1 grams | 8.7 % | |||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2021 ✔