Summary for Test 2021-07-22-11-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
Award Date | 03/22/2018 |
Closeout Date | 07/24/2023 |
Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
Location Description | SFOBB WEST SPAN |
QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
Sample Taken Date | 07/22/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/30/2021 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG |
The quantity of what the sample constitutes | 500 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Chuck | Last name of sampler or witnessed by | Franco |
Title of sampler | QA | Telephone number of sampler | 8585839270 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S73-015-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 422999A |
---|---|---|---|
Heat Number(s) | 100797433 | Nut Mfg. Lot Number(s) | 34664-212165 |
Washer Mfg. Lot Number(s) | 0220-393 | Bolt Specification | A325 |
Bolt Length(s) | 6" | Nut Specification | A563 |
Washer Specification | F436 | Finish | F2329 |
Diameter/Size | 1-1/8 | Bolt Mfg. Lot Number | 422999A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-07-22-11
DIME Test ID: 2021-07-22-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-08-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/02/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | 34664-212165 | 118935 | A563 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/3/2021 ✔