Summary for Test 2021-07-22-11-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 210037
DEA: 043G4424
EFIS: 0412000042
DIST-CO-RTE-PM04-SF-80-R5.6/7.6
Award Date03/22/2018
Closeout Date07/24/2023
Work DescriptionWEST SPAN DAMPER BRACKET A325 BOLT TESTING
Location DescriptionSFOBB WEST SPAN
QA Service Level1 (Verified on 11/04/2014)

Sample Information

Sample Taken Date07/22/2021 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/30/2021
Sample typeQuality Assurance A brief description of the sampleA325 HDG
The quantity of what the sample constitutes500 From where was the sample collectedDistributor
First name of sampler or witnessed byChuck Last name of sampler or witnessed byFranco
Title of samplerQA Telephone number of sampler8585839270
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePortland Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS73-015-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)422999A
Heat Number(s)100797433 Nut Mfg. Lot Number(s)34664-212165
Washer Mfg. Lot Number(s)0220-393 Bolt SpecificationA325
Bolt Length(s)6" Nut SpecificationA563
Washer SpecificationF436 FinishF2329
Diameter/Size1-1/8 Bolt Mfg. Lot Number422999A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-07-22-11
DIME Test ID: 2021-07-22-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-08-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/02/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1134664-212165118935A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/3/2021