Summary for Test 2021-07-19-27-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 214926 DEA: 010E7204 EFIS: 0115000003 |
---|---|
DIST-CO-RTE-PM | 01-LAK-29-12.7/14.5 |
Award Date | 07/07/2020 |
Closeout Date | 07/21/2022 |
Work Description | ROADWAY EXCAVATION, HMA (TYPE A), RHMA-G, DRAINAGE & EROSION CONTROL. |
Location Description | LAKE COUNTY NEAR LOWER LAKE FROM 0.8 MILE NORTH OF SPRUCE GROVE ROAD SOUTH TO 0.4 MILE SOUTH OF HOFACKER LANE |
QA Service Level | 1 (Verified on 06/10/2020) |
Sample Information
Sample Taken Date | 07/19/2021 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2021 |
Sample type | Department Acceptance | A brief description of the sample | PG64-16 |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | K | Last name of sampler or witnessed by | Poulter |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero | Transportation Laboratory (TL) Number | 724974 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-19-27
DIME Test ID: 2021-07-19-27-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-07-28
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/27/2021
Temperature: 25 C
Final Dial reading (F1): 94 mm
Ball Penetration (P1): 1 mm
Final Dial reading (F2): 95 mm
Ball Penetration (P2): 3 mm
Final Dial reading (F3): 90 mm
Ball Penetration (P3): 5 mm
Resilience 1: 7 %
Resilience 2: 8 %
Resilience 3: 15 %
Average Resilience: 10 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 7/28/2021 ✔