Summary for Test 2021-06-18-27-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 215253
DEA: 021J4804
EFIS: 0220000083
DIST-CO-RTE-PM02-SHA,TRI-36-8.0/11.912,27.1/R41.139
Award Date02/05/2021
Closeout Date09/30/2021
Work DescriptionASPHALT RUBBER CHIP SEAL AND TRAFFIC STRIPE.
Location DescriptionSHASTA AND TRINITY COUNTIES AT AND NEAR PLATINA FROM 0.4 MILE EAST OF MIDDLE FORK COTTONWOOD CREEK BRIDGE TO BEEGUM CREEK BRIDGE AND FROM 1.3 MILES EAST OF BRAMLET ROAD TO SHASTA COUNTY LINE
QA Service Level1 (Verified on 10/30/2020)

Sample Information

Sample Taken Date06/18/2021 Sample Unique Key27
Date that the sample was received by the laboratory/organization performing the testing07/26/2021 Sample typeDepartment Acceptance
A brief description of the samplePG 58-22 The quantity of what the sample constitutes1 OF 1 CAN
From where was the sample collectedSource First name of sampler or witnessed byMat
Last name of sampler or witnessed byB Title of samplerARE
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero - Benicia
Transportation Laboratory (TL) Number823532 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 58-22 Lot number
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-18-27
DIME Test ID: 2021-06-18-27-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-07-28

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/27/2021
Temperature: 25 C
Ball Penetration (P1): 3 mm
Final Dial reading (F1): 80 mm
Ball Penetration (P2): 4 mm
Final Dial reading (F2): 81 mm
Ball Penetration (P3): 3 mm
Final Dial reading (F3): 82 mm
Resilience 1: 23 %
Resilience 2: 23 %
Resilience 3: 21 %
Average Resilience: 22 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 7/28/2021 ✔