Summary for Test 2021-07-20-4-10
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
| Award Date | 03/22/2018 |
| Closeout Date | 07/24/2023 |
| Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
| Location Description | SFOBB WEST SPAN |
| QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
| Sample Taken Date | 07/20/2021 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2021 |
| Sample type | Quality Assurance | A brief description of the sample | 1 1/8" x 7 1/2" A325 fasteners with Nuts and washers |
| The quantity of what the sample constitutes | 110 assemblies | From where was the sample collected | Source |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Assoc Steel Inspector | Telephone number of sampler | 510-376-7155 cell |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | C835671 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-017-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 3407-01 |
|---|---|---|---|
| Heat Number(s) | Bolt-CR10377600 Nut 100897555 Washer A56619 | Nut Mfg. Lot Number(s) | Nucor 432090A |
| Washer Mfg. Lot Number(s) | Technical Stamping 0618-887 | Bolt Specification | A325 |
| Bolt Length(s) | 7 1/2" | Nut Specification | A563 Gr DH |
| Washer Specification | F436 | Finish | Hot Dip Galvanized |
| Diameter/Size | 1 1/8" | Bolt Mfg. Lot Number | Fontana 753270 |
| Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-07-20-4
DIME Test ID: 2021-07-20-4-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-07-28
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 07/27/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 753270
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: 1.125 in
Bolt Length: 7.5 in
Measurement Average: 2.63 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/28/2021 ✔