Summary for Test 2021-07-16-1-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/16/2021 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2021 |
| Sample type | Quality Assurance | A brief description of the sample | double end anchor bolts |
| The quantity of what the sample constitutes | 168 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 4156081742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMS Steel | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3101912 | Nut Mfg. Lot Number(s) | 202027 |
| Washer Mfg. Lot Number(s) | NLPY0735 | Bolt Specification | F1554 |
| Bolt Length(s) | 36" | Nut Specification | A194 |
| Washer Specification | F436 | Finish | HD |
| Diameter/Size | 1.0" | Bolt Mfg. Lot Number | CMC Steel |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-07-16-1
DIME Test ID: 2021-07-16-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-07-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/27/2021
UTM: 400kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1 | 34384-202027 | 106571 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 7/29/2021 ✔