Summary for Test 2021-06-11-30-1
Test performed: AASHTO T240-17Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/11/2021 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/16/2021 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder | The quantity of what the sample constitutes | 1 OF 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Valorie |
| Last name of sampler or witnessed by | Rice | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 1210602354 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Valero Benicia | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | 32 | |
| Time of sample | 0600 | HMA Supplier | |
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2021-06-11-30
DIME Test ID: 2021-06-11-30-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-07-22
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 07/21/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 171.436 grams
Mass of empty container #2: 167.188 grams
Mass of container #1 before test (m1i): 206.692 grams
Mass of container #2 before test (m2i): 203.560 grams
Mass of container #1 after test (m1f): 206.568 grams
Mass of container #2 after test (m2f): 203.432 grams
Average mass change: -0.352 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 7/22/2021 ✔