Summary for Test 2015-07-31-2-3

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Sample Information

Sample Taken Date07/31/2015 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/03/2015 Sample typeQuality Control
A brief description of the sample6x12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byC AND M
Last name of sampler or witnessed byDIKE AND TALEB Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification915-01
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJOB
Transportation Laboratory (TL) Number001 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameBRIDGE FOOTING FOR HINKLEY OC
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collectedNP The batch plant ticket number from where the sample was collectedNP
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-07-31-2
DIME Test ID: 2015-07-31-2-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-08-28

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/28/2015
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 128750 lb
Maximum load on cylinder 2: 130100 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4523.9 psi
Compressive strength of cylinder 2: 4571.3 psi
Compressive strength (to nearest 10 psi): 4550 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/28/2015 ✔