Summary for Test 2015-07-15-2-1
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 208862 DEA: 080K7104 EFIS: 0800000366 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15,215-14.0/R16.4,16.0/17.8 |
Award Date | 11/13/2012 |
Closeout Date | 02/13/2017 |
Work Description | I-15/I-215 Interchange Improvements (Devore) |
Location Description | On I-15 from 0.8 mile south of Glen Helen Parkway UC to 1.4 mile north of Kenwood Ave UC And On I-215 from 1.2 mile south of Devore Road OC to the I-15 junction |
QA Service Level | 1 (Verified on 06/10/2013) |
Sample Information
Sample Taken Date | 07/15/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | DARREN | Last name of sampler or witnessed by | HOPPER |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 868-03 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 180603 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | BRIDGE 5 DEVORE OH RT WIDEN |
Structure name | CIP DECK |
Material Information
Material Type | Concrete | The concrete mix design number | CT1-C4400DI |
---|---|---|---|
The truck number from where the sample was collected | 620 | The batch plant ticket number from where the sample was collected | 103037346 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-07-15-2
DIME Test ID: 2015-07-15-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-08-26
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/26/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 134670 lb
Maximum load on cylinder 2: 140200 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4746.9 psi
Compressive strength of cylinder 2: 4941.8 psi
Compressive strength (to nearest 10 psi): 4840 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/26/2015 ✔