Summary for Test 2021-07-12-8-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
| Award Date | 03/22/2018 |
| Closeout Date | 07/24/2023 |
| Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
| Location Description | SFOBB WEST SPAN |
| QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
| Sample Taken Date | 07/12/2021 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/13/2021 | Sample type | Quality Assurance |
| A brief description of the sample | 1" x 6" A325 Bolt Assembly | The quantity of what the sample constitutes | 59 Assemblies |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Greg |
| Last name of sampler or witnessed by | Thompson | Title of sampler | ASI |
| Telephone number of sampler | 510-376-7155 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Bay Bolt | |
| Transportation Laboratory (TL) Number | C835666 | Inspector Lot Number from the Transportation Laboratory (TL) Form | B09-006-21 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 2562-03 |
|---|---|---|---|
| Heat Number(s) | 10636610 100204968 203002 | Nut Mfg. Lot Number(s) | 443724D |
| Washer Mfg. Lot Number(s) | 10620 | Bolt Specification | A325 |
| Bolt Length(s) | 6" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | F2329 |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | L492N1 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2021-07-12-8
DIME Test ID: 2021-07-12-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-07-19
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 07/14/2021
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | L492N1 | 1.0000 | 86011 | 382.6 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/19/2021 ✔