Summary for Test 2021-05-10-31-3
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/10/2021 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/10/2021 |
Sample type | Quality Control | A brief description of the sample | PG58-16 Asphalt binder |
The quantity of what the sample constitutes | 2 of 2 cans, split sample | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Conner |
Title of sampler | Sr Asphalt Technician | Telephone number of sampler | 6614327352 |
Laboratory sample identification | PG5816-210510 | Linked DIME Sample ID | 2021-05-10-28 |
The fabricator/manufacturer/facility name | San Joaquin Refinery, Bakersfield, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 2002 | |
Time of sample | 8am | HMA Supplier | |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | PG 58-22 / PG 58-16 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-05-10-31
DIME Test ID: 2021-05-10-31-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-15
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/13/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.193 kPa
Phase Angle (δ) (for the 10 cycles): 89.0 degree
Complex Modulus (G*) (for the 10 measurements): 1.611 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.61 kPa
General comments (publicly viewable) (Max 1000 characters): ORIG
Test was verified on 7/15/2021 ✔