Summary for Test 2021-07-08-18-1
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 213099 DEA: 041A6614 EFIS: 0415000291 COOP: 042683A1 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-8.4 |
| Award Date | 11/30/2020 |
| Closeout Date | 12/12/2023 |
| Work Description | CONSTRUCTION ON STATE HIGHWAY IN MARIN COUNTY IN LARKSPUR |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/06/2020) |
Sample Information
| Sample Taken Date | 07/08/2021 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/09/2021 |
| Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | ||
| Group Number | 10971 | Strand Diameter | .6 in |
| Grade | 270 | Strand Specification | ASTM A 882 |
| Heat Number(s) | S0508919, S0572819 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2021-07-08-18
DIME Test ID: 2021-07-08-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-07-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 07/09/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0508919 | S334887-2-1 | 0.213 | 59510 | 54576.8 | 28.4 | 1.86 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 7/9/2021 ✔