Summary for Test 2021-06-17-41-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212777 DEA: 021H1104 EFIS: 0215000106 |
---|---|
DIST-CO-RTE-PM | 02-LAS-299-25.58/25.58 |
Award Date | 12/04/2019 |
Closeout Date | 08/14/2023 |
Work Description | BUILDING WORK. |
Location Description | LASSEN COUNTY ABOUT 11 MILES EAST OF BIEBER AT THE ADIN MAINTENANCE STATION |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 06/17/2021 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2021 |
Sample type | Department Acceptance | A brief description of the sample | Lime Treated 1/2-inch Type A HMA (eq. PG 64-28 M) with 10.0% RAP and virgin PG 64-28 M binder from Albina - Klamath Falls |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Emilio | Last name of sampler or witnessed by | Chavez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78846 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Eagle Peak Rock and Paving, Alturas, CA | Transportation Laboratory (TL) Number | 766442 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-17-41
DIME Test ID: 2021-06-17-41-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-01-14
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 06/21/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1545.2 grams
Mass of container filled with the sample and water for Sample 1: 8246.8 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.433
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/14/2022 ✔