Summary for Test 2021-05-06-26-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214874
DEA: 022H0504
EFIS: 0216000093
DIST-CO-RTE-PM02-TRI-36-R34.8/R35.4
Award Date05/27/2020
Closeout Date09/27/2021
Work DescriptionREALIGN ROADWAY, DRAINAGE, GUARDRAIL, AND EROSION CONTROL.
Location DescriptionTRINITY COUNTY ABOUT 15 MILES WEST OF PLATINA FROM 3.6 MILES TO 2.9 MILES WEST OF HAYFORK CREEK BRIDGE.
QA Service Level1 (Verified on 05/26/2020)

Sample Information

Sample Taken Date05/06/2021 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing05/06/2021 Sample typeDepartment Acceptance
A brief description of the sampleTreated Virgin 3/4-inch Type A Aggregate The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byCindy
Last name of sampler or witnessed byBryant Title of sampler
Telephone number of sampler Laboratory sample identificationD78792A
Linked DIME Sample ID The fabricator/manufacturer/facility nameKnife River Construction - Orland Plant
Transportation Laboratory (TL) Number768790 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-11-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 20-02-P03 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-06-26
DIME Test ID: 2021-05-06-26-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-07-02

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Karen Rios Dorado
Date of test: 05/07/2021
Cumulative Mass RetainedCumulative Percent Passing
6640.0 grams
grams %
0.0 grams100 %
0.0 grams100 %
191.0 grams97.1 %
1578.0 grams76.2 %
2386.0 grams64.1 %
3336 grams49.8 %
3814.0 grams42.6 %
191.6 grams26.6 %
305.5 grams17.1 %
374.9 grams11.2 %
422.5 grams7.3 %
458.7 grams4.2 %
478.8 grams2.56 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2021 ✔