Summary for Test 2021-06-09-31-5

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 993103
DEA: 021J7504
EFIS: 0220000124
DIST-CO-RTE-PM02-LAS-36-14.5/16.8
Award DateNot set
Closeout DateNot set
Work DescriptionDevil's Corral Safety
Location DescriptionNot set
QA Service Level1 (Verified on 08/02/2021)

Sample Information

Sample Taken Date06/09/2021 Sample Unique Key31
Date that the sample was received by the laboratory/organization performing the testing06/10/2021 Sample typePreliminary
A brief description of the sampleSoil Structural Section Recommendation The quantity of what the sample constitutesStructural Section Recommendation
From where was the sample collectedJob Site First name of sampler or witnessed byBrian
Last name of sampler or witnessed bySteiner Title of samplerAAME
Telephone number of sampler Laboratory sample identificationD78841
Linked DIME Sample ID The fabricator/manufacturer/facility nameNot applicable
Transportation Laboratory (TL) Number824590 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameNot Applicable
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collected02-LAS-36-16.6 on Rt Shoulder 20 ft off EP
Where the material sample would have been placed if not sampled02 LAS 36

Test Details

DIME Sample ID: 2021-06-09-31
DIME Test ID: 2021-06-09-31-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-12-28

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/21/2021
Minimum soil resistance of the lab measurement: 3000 Ohms
Soil sample temperature: 22.6 C
Soil box constant: 1
pH of soil: 6.46
Minimum soil resistance corrected to 15.5: 3532.5 Ohm-cm
Minimum soil resistivity at 15.5: 3533 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/28/2021 ✔