Summary for Test 2021-06-09-30-5
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 993103 DEA: 021J7504 EFIS: 0220000124 |
|---|---|
| DIST-CO-RTE-PM | 02-LAS-36-14.5/16.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Devil's Corral Safety |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
| Sample Taken Date | 06/09/2021 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/10/2021 | Sample type | Preliminary |
| A brief description of the sample | 2 bags of Soil | The quantity of what the sample constitutes | Structural Section Recommendation |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Steiner | Title of sampler | AAME |
| Telephone number of sampler | Laboratory sample identification | D78840 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Not applicable | |
| Transportation Laboratory (TL) Number | 824589 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | Not Applicable | |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-LAS-36-15.5 on Rt Shoulder 30 ft off EP | |
| Where the material sample would have been placed if not sampled | 02 LAS 36 |
Test Details
DIME Sample ID: 2021-06-09-30
DIME Test ID: 2021-06-09-30-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-12-28
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/21/2021
Minimum soil resistance of the lab measurement: 1400 Ohms
Soil sample temperature: 22.3 C
Soil box constant: 1
pH of soil: 6.53
Minimum soil resistance corrected to 15.5: 1638 Ohm-cm
Minimum soil resistivity at 15.5: 1638 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/28/2021 ✔
