Summary for Test 2021-04-28-29-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 212914
DEA: 031E0604
EFIS: 0312000068
DIST-CO-RTE-PM03-YUB-70-15.5/16.5
Award Date07/31/2019
Closeout Date08/30/2023
Work DescriptionSIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location DescriptionNEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
QA Service Level1 (Verified on 08/22/2019)

Sample Information

Sample Taken Date04/28/2021 Sample Unique Key29
Date that the sample was received by the laboratory/organization performing the testing04/28/2021 Sample typeVerification
A brief description of the sample3/4" RHMA-G The quantity of what the sample constitutes12 Boxes, JMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byTeichert Personnel (SAMPLER)
Last name of sampler or witnessed byKen McHugh (WITNESS) Title of sampler
Telephone number of sampler Laboratory sample identificationJMF21-024
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert-Hallwood Plant
Transportation Laboratory (TL) NumberC741863 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-04-28-29
DIME Test ID: 2021-04-28-29-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-06-29

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Terrance White
Date of test: 06/09/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2170.8 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 2002.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.40 %
General comments (publicly viewable) (Max 1000 characters): JMF21-024.

Test was verified on 6/29/2021 ✔