Summary for Test 2021-06-02-24-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Award Date05/15/2020
Closeout Date12/13/2023
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date06/02/2021 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing06/21/2021 Sample typeDepartment Acceptance
A brief description of the sample1st TEST The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byBrad
Last name of sampler or witnessed byMcKeehan Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero Benicia
Transportation Laboratory (TL) Number706334 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierDeSilva Gates
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-06-02-24
DIME Test ID: 2021-06-02-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-06-29

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 06/25/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 167.090 grams
Mass of empty container #2: 172.658 grams
Mass of container #1 before test (m1i): 202.173 grams
Mass of container #2 before test (m2i): 207.609 grams
Mass of container #1 after test (m1f): 201.976 grams
Mass of container #2 after test (m2f): 207.406 grams
Average mass change: -0.571 percent
General comments (publicly viewable) (Max 1000 characters): per standard specifications

Test was verified on 6/29/2021 ✔