Summary for Test 2021-03-30-31-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 215296
DEA: 031F1504
EFIS: 0300001101
DIST-CO-RTE-PM03-SAC-50-R7.7/R9.5
Award Date02/05/2021
Closeout Date10/04/2022
Work DescriptionPLACE HMA, RHMA, AGGREGATE BASE AND FIBER OPTIC SYSTEM.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR RANCHO CORDOVA FROM BRADSHAW ROAD OVERCROSSING TO MATHER FIELD OVERCROSSING
QA Service Level1 (Verified on 11/30/2020)

Sample Information

Sample Taken Date03/30/2021 Sample Unique Key31
Date that the sample was received by the laboratory/organization performing the testing03/30/2021 Sample typeVerification
A brief description of the sample3/4" HMA - A The quantity of what the sample constitutes12 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byTeichert Personnel (SAMPLER)
Last name of sampler or witnessed bySam Mosallem (WITNESS) Title of sampler
Telephone number of sampler Laboratory sample identificationJMF21-019
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Perkins Batch Plant
Transportation Laboratory (TL) NumberC790491 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-03-30-31
DIME Test ID: 2021-03-30-31-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-06-17

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Kavon Rastegar
Date of test: 05/18/2021
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

148 psi

182 psi

0.81
General comments (publicly viewable) (Max 1000 characters): JMF21-019. Jeff Herbert

Test was verified on 6/17/2021 ✔