Summary for Test 2021-06-02-14-6
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 215424 DEA: 024G4404 EFIS: 0214000013 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3-38.0/38.6 |
Award Date | 04/05/2021 |
Closeout Date | 08/14/2023 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD |
QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
Sample Taken Date | 06/02/2021 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/14/2021 |
Sample type | Department Acceptance | A brief description of the sample | Test binder #2 |
The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Owens |
Title of sampler | PEI Tech | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | 779364 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-02-14
DIME Test ID: 2021-06-02-14-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-17
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/15/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.246 kPa
Phase Angle (δ) (for the 10 cycles): 84.1 degree
Complex Modulus (G*) (for the 10 measurements): 2.047 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.06 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications test#2 ORIG
Test was verified on 6/17/2021 ✔