Summary for Test 2021-06-07-21-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215251
DEA: 021J4604
EFIS: 0220000081
DIST-CO-RTE-PM02-SIS-96-34.5/38.8,88.0/92.0
Award Date02/02/2021
Closeout Date09/27/2021
Work DescriptionHMA OVERLAY, REPLACE AC SURFACING, SHOULDER BACKING & TRAFFIC STRIPE.
Location DescriptionSISKIYOU COUNTY NEAR HAPPY CAMP FROM 0.1 MILE EAST OF OAK FLAT CREEK BRIDGE TO 0.1 MILE EAST OF BENJAMIN CREEK ROAD AND FROM 0.3 MILE WEST OF BEAVER CREEK BRIDGE TO 1.0 MILE WEST OF LUMGREY CREEK BRIDGE
QA Service Level1 (Verified on 10/30/2020)

Sample Information

Sample Taken Date06/07/2021 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing06/08/2021 Sample typeDepartment Acceptance
A brief description of the samplePSE RAP The quantity of what the sample constitutes150 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byD.
Last name of sampler or witnessed byOwens Title of samplerPEI
Telephone number of sampler Laboratory sample identificationD78835
Linked DIME Sample ID2021-06-07-20 The fabricator/manufacturer/facility nameTullis Inc, Northstate Asphalt, Redding CA
Transportation Laboratory (TL) Number779371 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceUnknown
Aggregate Size1/2-inch Aggregate SourceUnknown
RAP StockpileContinuous Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-07-21
DIME Test ID: 2021-06-07-21-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-11-02

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 06/09/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1613.6 grams
Mass of container filled with the sample and water for Sample 1: 8319.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.558
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/2/2021 ✔