Summary for Test 2021-06-10-15-3
Test performed: ASTM C1064-17Project Information
Project Identifiers | Project ID: 215075 DEA: 060Q9104 EFIS: 0614000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-19.2/19.8 |
Award Date | 09/25/2020 |
Closeout Date | 05/11/2023 |
Work Description | BRIDGE DECK AND OUTSIDE GIRDER REPLACEMENT. |
Location Description | TULARE COUNTY NEAR TIPTON FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF AVENUE 152 OVERCROSSING |
QA Service Level | 1 (Verified on 07/28/2020) |
Sample Information
Sample Taken Date | 06/10/2021 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2021 |
Sample type | Quality Control | A brief description of the sample | PCC 6"x12" test cylinder |
The quantity of what the sample constitutes | One girder | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Roberto | Last name of sampler or witnessed by | Reyes |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Con-Fab California LLC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SCCS980F |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1309 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Casting Bed 1 | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-06-10-15
DIME Test ID: 2021-06-10-15-3
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2021-06-15
Test Results
Input Type: Calculated
Tester's full name: Roberto Reyes Perez
Date of test: 06/10/2021
Temperature: 77 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/15/2021 ✔