Summary for Test 2021-06-02-13-10
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 215297 DEA: 042J8304 EFIS: 0415000006 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80,580,880-Var |
| Award Date | 12/30/2020 |
| Closeout Date | 12/07/2023 |
| Work Description | MODIFYING TRAFFIC MONITORING STATIONS. TMS REPLACE AND UPGRADE AT MAZE |
| Location Description | ALAMEDA COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 11/09/2020) |
Sample Information
| Sample Taken Date | 06/02/2021 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2021 |
| Sample type | Quality Assurance | A brief description of the sample | F1554 Anchor Rods Nuts Washers |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Lewis |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Madden Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3101507 190483 209034 | Nut Mfg. Lot Number(s) | XSF2 |
| Washer Mfg. Lot Number(s) | 6186 | Bolt Specification | F1554 GR55 |
| Bolt Length(s) | 55" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 3" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-06-02-13
DIME Test ID: 2021-06-02-13-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-07-14
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 06/10/2021
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: XSF2
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH D/N
Size: 3 in
Bolt Length: no data
Measurement Average: 5.64 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/14/2021 ✔