Summary for Test 2021-06-02-13-7
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 215297 DEA: 042J8304 EFIS: 0415000006 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80,580,880-Var |
| Award Date | 12/30/2020 |
| Closeout Date | 12/07/2023 |
| Work Description | MODIFYING TRAFFIC MONITORING STATIONS. TMS REPLACE AND UPGRADE AT MAZE |
| Location Description | ALAMEDA COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 11/09/2020) |
Sample Information
| Sample Taken Date | 06/02/2021 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/09/2021 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Anchor Rods Nuts Washers | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Justin |
| Last name of sampler or witnessed by | Lewis | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Madden Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3101507 190483 209034 | Nut Mfg. Lot Number(s) | XSF2 |
| Washer Mfg. Lot Number(s) | 6186 | Bolt Specification | F1554 GR55 |
| Bolt Length(s) | 55" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 3" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2021-06-02-13
DIME Test ID: 2021-06-02-13-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-07-14
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 06/10/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 3101507 190483 209034
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW
Size: 3 in
Bolt Length: 55 in
Measurement Average: 5.23 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/14/2021 ✔