Summary for Test 2021-04-13-31-5

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 212496
DEA: 024E4504
EFIS: 0200020286
DIST-CO-RTE-PM02-LAS,MOD-139,299-VAR
Award Date07/28/2020
Closeout Date08/14/2023
Work DescriptionPLACE HMA, REPLACE DRAINAGE, CULVERT, ELECTRICAL AND LIGHTING SYSTEMS.
Location DescriptionLASSEN AND MODOC COUNTIES ON ROUTE 139 AT 0.1 MILE NORTH OF LASSEN COUNTY LINE AND ON ROUTE 299 AT VARIOUS LOCATONS FROM 0.4 MILE WEST OF BOYD HILL LOOKOUT ROAD TO 0.6 MILE EAST OF COUNTY ROAD 87
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date04/13/2021 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/14/2021
Sample typeVerification A brief description of the sample3/4-inch Type A Untreated Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of sampler Telephone number of sampler
Laboratory sample identificationD78777F Linked DIME Sample ID
The fabricator/manufacturer/facility nameShaw Pit - Lookout, CA Transportation Laboratory (TL) Number037263
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-25-0008
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF21-03-S01 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-13-31
DIME Test ID: 2021-04-13-31-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-06-10

Test Results


Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/04/2021
Mass of saturated surface dry sample (before pycnometer) (S): 502.6 grams
Mass of the pycnometer with water and aggregate (C): 974.9 grams
Mass of the pycnometer with water (B): 662.9 grams
Mass of the oven dried sample (before pycnometer) (A): 487.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 502.6 grams
Mass of the oven dry aggregate (for absorption) (A): 487.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.556
Bulk specific gravity (SSD Basis): 2.637
Apparent specific gravity: 2.781
Absorption: 3.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/10/2021