Summary for Test 2021-06-07-1-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 215257 DEA: 11056374 EFIS: 1117000087 |
---|---|
DIST-CO-RTE-PM | 11-SD-11-0.6/2.7 |
Award Date | 02/16/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT INTERCHANGE, PLACE JPCP, HMA, AND INSTALL LIGHTING. |
Location Description | SAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 1.2 MILE EAST OF ENRICO FERMI DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 11/25/2020) |
Sample Information
Sample Taken Date | 06/07/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2021 |
Sample type | Quality Assurance | A brief description of the sample | HRC 555 T-Heads |
The quantity of what the sample constitutes | 56 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC San Bernardino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-094-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 1066929 | Head Manufacturer Lot Number(s) | 1 |
Rebar Size | #14 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | CMC Rancho Cucamonga |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-06-07-1
DIME Test ID: 2021-06-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-06-10
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/09/2021
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 2.25 | 210357 | 93492 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/10/2021 ✔