Summary for Test 2021-05-27-30-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 212496
DEA: 024E4504
EFIS: 0200020286
DIST-CO-RTE-PM02-LAS,MOD-139,299-VAR
Award Date07/28/2020
Closeout Date08/14/2023
Work DescriptionPLACE HMA, REPLACE DRAINAGE, CULVERT, ELECTRICAL AND LIGHTING SYSTEMS.
Location DescriptionLASSEN AND MODOC COUNTIES ON ROUTE 139 AT 0.1 MILE NORTH OF LASSEN COUNTY LINE AND ON ROUTE 299 AT VARIOUS LOCATONS FROM 0.4 MILE WEST OF BOYD HILL LOOKOUT ROAD TO 0.6 MILE EAST OF COUNTY ROAD 87
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date05/27/2021 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing06/01/2021 Sample typeDepartment Acceptance
A brief description of the sampleRAP The quantity of what the sample constitutes328 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byE.
Last name of sampler or witnessed byChavez Title of sampler
Telephone number of sampler Laboratory sample identificationD78816
Linked DIME Sample ID2021-05-27-29 The fabricator/manufacturer/facility nameHat Creek - Shaw Pit Facility
Transportation Laboratory (TL) Number823554 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceShaw Pit Facility
Aggregate Size3/8 inch minus Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-27-30
DIME Test ID: 2021-05-27-30-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-08-12

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 06/02/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 7.05 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/12/2021 ✔