Summary for Test 2021-05-28-2-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215424 DEA: 024G4404 EFIS: 0214000013 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3-38.0/38.6 |
Award Date | 04/05/2021 |
Closeout Date | 08/14/2023 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD |
QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
Sample Taken Date | 05/28/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2021 |
Sample type | Quality Assurance | A brief description of the sample | #6 2'6" Dia Hoops |
The quantity of what the sample constitutes | 8 lots (1200 hoops) | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-161-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1201028406 |
Hoop Manufacturer Lot Number(s) | 1, 2 and 7 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #6 |
Diameter of Hoop | 2'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-05-28-2
DIME Test ID: 2021-05-28-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-06-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/07/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | 6/19mm | 0.44 | 41654.05 | 94668 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/7/2021 ✔