Summary for Test 2021-05-28-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date05/28/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/04/2021
Sample typeQuality Assurance A brief description of the sample#6 2'6" Dia Hoops
The quantity of what the sample constitutes8 lots (1200 hoops) From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-161-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201028406
Hoop Manufacturer Lot Number(s)1, 2 and 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-05-28-2
DIME Test ID: 2021-05-28-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-06-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/07/2021
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1216/19mm0.4441654.0594668OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 6/7/2021