Summary for Test 2015-07-22-1-2
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209059 DEA: 033E1004 EFIS: 0300000473 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-8.1/37.8 |
Award Date | 01/28/2014 |
Closeout Date | 01/23/2017 |
Work Description | IMPROVING VERTICAL CLEARANCE |
Location Description | PLACER COUNTY IN AND NEAR LOOMIS, PENRYN, NEWCASTLE, WEIMAR, AND MAGRA FROM 0.1 MILE WEST OF BRACE ROAD OVERCROSSING TO 0.1 MILE EAST OF MAGRA OVERCROSSING |
QA Service Level | 1 (Verified on 01/15/2014) |
Sample Information
Sample Taken Date | 07/22/2015 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/23/2015 |
Sample type | Quality Control | A brief description of the sample | concrete |
The quantity of what the sample constitutes | concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | mike | Last name of sampler or witnessed by | morgan |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 80053 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | Unknown |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | Unknown |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | from mix truck | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-07-22-1
DIME Test ID: 2015-07-22-1-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-07-29
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 07/29/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 111404 lb
Maximum load on cylinder 2: 111020 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3926.8 psi
Compressive strength of cylinder 2: 3900.9 psi
Compressive strength (to nearest 10 psi): 3910 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 7/29/2015 ✔