Summary for Test 2021-05-28-10-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
| Award Date | 04/21/2020 |
| Closeout Date | 12/02/2025 |
| Work Description | Panther Creek & Hunter Creek Bridges |
| Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
| Sample Taken Date | 05/28/2021 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/02/2021 |
| Sample type | Quality Assurance | A brief description of the sample | Couplers |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | R | Last name of sampler or witnessed by | Parr |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC HRC | Transportation Laboratory (TL) Number | C725805 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-060-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | |
| Rebar Size | #9 | Coupler Model | HRC 500/520 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A205153 74120293 | Rebar Heat Number(s) | 6021607 |
| Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-05-28-10
DIME Test ID: 2021-05-28-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-06-02
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/02/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | No. 9/29mm | 1 | 0 | 1 | 98728 | 98728 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 6/2/2021 ✔
