Summary for Test 2021-03-19-24-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 215405
DEA: 032G1604
EFIS: 0320000235
DIST-CO-RTE-PM03-YOL-45-0.6/12.9
Award Date02/16/2021
Closeout Date06/30/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT.
Location DescriptionYOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD
QA Service Level1 (Verified on 01/18/2021)

Sample Information

Sample Taken Date03/19/2021 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing03/19/2021 Sample typeVerification
A brief description of the sample3/4" HMA - A w/RAP The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byTeichert Personnel (SAMPLER)
Last name of sampler or witnessed bySam Mosallem (WITNESS) Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationJMF21-015
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert - Woodland Plant
Transportation Laboratory (TL) NumberC849138 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-03-19-24
DIME Test ID: 2021-03-19-24-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-05-28

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Kavon Rastegar
Date of test: 05/05/2021
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

151 psi

187 psi

0.81
General comments (publicly viewable) (Max 1000 characters): JMF21-015. Jeff Herbert

Test was verified on 5/28/2021 ✔